ntp: add options to set minsamples/maxsamples of hwclock
This commit is contained in:
@@ -1945,6 +1945,12 @@ It's defined as a power of two. It should correspond to the minimum polling
|
||||
interval of all NTP sources and the minimum expected polling interval of NTP
|
||||
clients. The default value is 0 (1 second) and the minimum value is -6 (1/64th
|
||||
of a second).
|
||||
*minsamples* _samples_:::
|
||||
This option specifies the minimum number of readings kept for tracking of the
|
||||
NIC clock. The default value is 2.
|
||||
*maxsamples* _samples_:::
|
||||
This option specifies the maximum number of readings kept for tracking of the
|
||||
NIC clock. The default value is 16.
|
||||
*precision* _precision_:::
|
||||
This option specifies the assumed precision of reading of the NIC clock. The
|
||||
default value is 100e-9 (100 nanoseconds).
|
||||
|
||||