mirror of
https://gitlab.com/chrony/chrony.git
synced 2025-12-07 15:55:07 -05:00
Add lock option for PPS refclocks
This commit is contained in:
@@ -2289,6 +2289,12 @@ PPS signal frequency (in Hz). This option only controls how the
|
||||
received pulses are aligned. To actually receive more than one
|
||||
pulse per second, a negative @code{dpoll} has to be specified (-3 for
|
||||
5Hz signal). The default is 1.
|
||||
@item lock
|
||||
This option can be used to lock a PPS refclock to another refclock
|
||||
whose reference id is specified by this option. In this mode received
|
||||
pulses are aligned directly to unfiltered samples from the refclock.
|
||||
By default, pulses are aligned to local clock, but only when it is
|
||||
well synchronised.
|
||||
@item offset
|
||||
This option can be used to compensate a constant error. The specified
|
||||
offset (in seconds) is applied to all samples produced by the
|
||||
|
||||
Reference in New Issue