logging: remove facility parameter
It was never used for anything and messages in debug output already include filenames, which can be easily grepped if there is a need to see log messages only from a particular file.
This commit is contained in:
@@ -143,7 +143,7 @@ HCL_AccumulateSample(HCL_Instance clock, struct timespec *hw_ts,
|
||||
|
||||
if (hw_delta <= 0.0 || local_delta < clock->min_separation / 2.0) {
|
||||
clock->n_samples = 0;
|
||||
DEBUG_LOG(LOGF_HwClocks, "HW clock reset interval=%f", local_delta);
|
||||
DEBUG_LOG("HW clock reset interval=%f", local_delta);
|
||||
}
|
||||
|
||||
for (i = MAX_SAMPLES - clock->n_samples; i < MAX_SAMPLES; i++) {
|
||||
@@ -165,7 +165,7 @@ HCL_AccumulateSample(HCL_Instance clock, struct timespec *hw_ts,
|
||||
&n_runs, &best_start);
|
||||
|
||||
if (!clock->valid_coefs) {
|
||||
DEBUG_LOG(LOGF_HwClocks, "HW clock needs more samples");
|
||||
DEBUG_LOG("HW clock needs more samples");
|
||||
return;
|
||||
}
|
||||
|
||||
@@ -177,12 +177,12 @@ HCL_AccumulateSample(HCL_Instance clock, struct timespec *hw_ts,
|
||||
/* If the fit doesn't cross the error interval of the last sample, throw away
|
||||
all previous samples and keep only the frequency estimate */
|
||||
if (fabs(clock->offset) > err) {
|
||||
DEBUG_LOG(LOGF_HwClocks, "HW clock reset offset=%e", clock->offset);
|
||||
DEBUG_LOG("HW clock reset offset=%e", clock->offset);
|
||||
clock->offset = 0.0;
|
||||
clock->n_samples = 1;
|
||||
}
|
||||
|
||||
DEBUG_LOG(LOGF_HwClocks, "HW clock samples=%d offset=%e freq=%.9e raw_freq=%.9e err=%e ref_diff=%e",
|
||||
DEBUG_LOG("HW clock samples=%d offset=%e freq=%.9e raw_freq=%.9e err=%e ref_diff=%e",
|
||||
clock->n_samples, clock->offset, clock->frequency, raw_freq, err,
|
||||
UTI_DiffTimespecsToDouble(&clock->hw_ref, &clock->local_ref));
|
||||
}
|
||||
|
||||
Reference in New Issue