<P>In WBEM V1, whenever a standalone (local or remote) instance, class, method, or property provider shut down, CIMOM was not able to use this provider again. Starting with WBEM build 619, this problem is fixed. </p>
<p>Whenever a request to a provider returns an error code with a facility other than FACILITY_ITF (all documented WBEM error codes have this facility), CIMOM assumes that a system problem is preventing communications with a provider, releases the provider, reconnects, and re-issues the request. If the request fails again, no further attempts are made and the request fails.</P>
<p>This behavior was already implemented in V1 for event consumers. <strong>This behavior is not supported for event providers: once an event provider is down, it will not be restarted again</strong>