@@ -165,6 +165,13 @@ versions or implementations of the libraries might make different system calls.
|
||||
If the filter is missing some system call, `chronyd` could be killed even in
|
||||
normal operation.
|
||||
|
||||
The impact of potential security issues in `chronyc` can be reduced by running
|
||||
`chronyc` under the _chrony_ user instead of root, or another unprivileged user
|
||||
if access to the Unix domain socket is not needed. Since version 4.8, `chronyc`
|
||||
drops root privileges automatically if it is started with the `-u` option
|
||||
specifying the _chrony_ user, or the name was specified to be the compiled-in
|
||||
default by the `--with-chronyc-user` option of the configure script.
|
||||
|
||||
=== How can I make the system clock more secure?
|
||||
|
||||
An NTP client synchronising the system clock to an NTP server is susceptible to
|
||||
@@ -897,7 +904,9 @@ measurements from both sources.
|
||||
|
||||
If the first source was significantly better than the second source, it can
|
||||
take many hours before the second source is selected, depending on its polling
|
||||
interval. You can force a faster reselection by increasing the clock error rate
|
||||
interval. You can force a faster reselection by reducing the maximum number of
|
||||
polls the source can still be selected when unreachable (`maxunreach` option
|
||||
supported since `chrony` version 4.8), increasing the clock error rate
|
||||
(`maxclockerror` directive), shortening the polling interval (`maxpoll`
|
||||
option), or reducing the number of samples (`maxsamples` option).
|
||||
|
||||
|
||||