Previously, in the calculation of the next transmission time corresponding to the current polling interval, the reference point was the current time in the client mode (i.e. the time when the response is processed) and the last transmission time in the symmetric mode. Rework the code to use the last transmission in both modes and make it independent from the time when the response is processed to avoid extra delays due to waiting for HW TX timestamps.