If chronyc sent a request which caused chronyd to step the clock (e.g. makestep, settime) and the second reading of the clock before calling select() to wait for a response happened after the clock was stepped, a new request could be sent immediately and chronyd would process the same command twice. If the second request failed (e.g. a settime request too close to the first request), chronyc would report an error. Change the submit_request() function to read the clock only once per select() to wait for the first response even when the clock was stepped.